Archive

UDK: 666.974.001.4
DOI: n/a

Published: Građevinar 61 (2009) 7
Paper type: Preliminary report
Download article (Croatian): n/a
Download article (English): n/a

Testing polymer modified concrete by non-destructive methods

Ivana Banjad Pečur, Nina Štirmer, Jure Galić

Abstract

The polymer modified concrete is often used for the remedy of existing reinforced-concrete structures. Results of laboratory testing conducted on 20 different concrete mix compositions are presented in the paper. The water-cement ratio, aggregate grain size, and polymer content in concrete, were all varied in the course of the testing. The dependence between mechanical properties of concrete tested by destructive testing and that tested by non-destructive methods was determined, and this by defining the sclerometer index and by measuring velocity of ultrasound impulse.

Keywords
sclerometer index, ultrasound impulse, polymer modified concrete, laboratory testing, non-destructive test methods

HOW TO CITE THIS ARTICLE:

Banjad Pečur, I. ., Štirmer, N., Galić, J.: Testing polymer modified concrete by non-destructive methods, GRAĐEVINAR, 61 (2009) 7

OR:

Banjad Pečur, I. ., Štirmer, N., Galić, J. (2009). Testing polymer modified concrete by non-destructive methods, GRAĐEVINAR, 61 (7)
Authors:
Ivana Banjad Pecur WEB
Ivana Banjad Pečur
University of Zagreb,
Faculty of Civil Engineering,
Department of Materials

Nina Štirmer
University of Zagreb,
Faculty of Civil Engineering,
Department of Materials

Jure Galić